{"id":3297,"date":"2026-06-03T09:49:36","date_gmt":"2026-06-03T09:49:36","guid":{"rendered":"https:\/\/gearboxesworm.xyz\/worm-gearbox-for-chemical-dosing-pump\/"},"modified":"2026-06-03T09:49:36","modified_gmt":"2026-06-03T09:49:36","slug":"worm-gearbox-for-chemical-dosing-pump","status":"publish","type":"post","link":"https:\/\/gearboxesworm.xyz\/th\/worm-gearbox-for-chemical-dosing-pump\/","title":{"rendered":"Worm Gearbox for Chemical Dosing Pump"},"content":{"rendered":"<h2 style=\"color:#3a1a5c;font-size:1.45em;margin:26px 0 10px;padding:8px 0 8px 14px;border-left:5px solid #3a1a5c;background:linear-gradient(to right,#3a1a5c18,transparent);\">Worm Gearbox for Chemical Dosing Pump \u2014 Precise, Corrosion-Resistant Metering Drive<\/h2>\n<p style=\"line-height:1.8;\">Chemical dosing pumps in water treatment plants precisely deliver chlorine, sodium hypochlorite, polymers, lime slurry, and pH-adjustment acids at accurately controlled feed rates. A <strong>worm gear speed reducer<\/strong> driving a metering pump must provide stable, vibration-free output at very low speeds (often below 30 rpm); resistance to chemical attack from dosing chemical spillage or vapour; and zero-backlash motion transmission for accurate dose control. The inherent self-locking of the worm gear also prevents siphoning \u2014 backward flow through the pump when the drive stops. Visit our <a href=\"https:\/\/gearboxesworm.xyz\/th\/applications\/\" style=\"color:#3a1a5c;\">applications page<\/a> for more water industry solutions.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/gearboxesworm.xyz\/wp-content\/uploads\/2026\/06\/water-treatment-application.webp\" alt=\"worm gearbox chemical dosing pump water treatment corrosion resistant drive\" style=\"max-width:100%;height:auto;border-radius:8px;margin:16px 0;\"><\/p>\n<h2 style=\"color:#3a1a5c;font-size:1.45em;margin:26px 0 10px;padding:8px 0 8px 14px;border-left:5px solid #3a1a5c;background:linear-gradient(to right,#3a1a5c18,transparent);\">Chemical Environments: Material Selection Matrix<\/h2>\n<p style=\"line-height:1.8;\">Chemical dosing environments impose some of the most aggressive exposures in water treatment: chlorine gas and hypochlorite attack standard aluminium alloy housings within months; fluoride solutions require PTFE-lined components; sulphuric acid used for pH correction rapidly corrodes carbon steel shafts. There is no single material that resists all dosing chemicals \u2014 correct specification requires matching housing, shaft, and seal materials to the specific chemical environment.<\/p>\n<div style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:16px 0;\">\n<table style=\"width:100%;border-collapse:collapse;min-width:580px;\">\n<tr>\n<th style=\"padding:10px 14px;background-color:#3a1a5c;color:white;font-weight:bold;text-align:left;border:1px solid #ccc;\">Chemical<\/th>\n<th style=\"padding:10px 14px;background-color:#3a1a5c;color:white;font-weight:bold;text-align:left;border:1px solid #ccc;\">Housing<\/th>\n<th style=\"padding:10px 14px;background-color:#3a1a5c;color:white;font-weight:bold;text-align:left;border:1px solid #ccc;\">Shaft<\/th>\n<th style=\"padding:10px 14px;background-color:#3a1a5c;color:white;font-weight:bold;text-align:left;border:1px solid #ccc;\">Seal<\/th>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Sodium hypochlorite (NaOCl)<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Epoxy cast iron or PVDF<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">316L SS<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">FKM Viton<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">Chlorine gas (Cl\u2082)<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">316L SS or PVDF<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">Hastelloy C276<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">PTFE<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Sulphuric acid (H\u2082SO\u2084)<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Epoxy cast iron<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">316L SS<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">FKM Viton<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">Lime slurry Ca(OH)\u2082<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">Abrasion-resistant cast iron<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">Chrome alloy steel<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">NBR or FKM<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Polymer flocculant<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Standard cast iron<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Standard alloy steel<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">NBR<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<h2 style=\"color:#3a1a5c;font-size:1.45em;margin:26px 0 10px;padding:8px 0 8px 14px;border-left:5px solid #3a1a5c;background:linear-gradient(to right,#3a1a5c18,transparent);\">Technical Specifications<\/h2>\n<div style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:16px 0;\">\n<table style=\"width:100%;border-collapse:collapse;min-width:580px;\">\n<tr>\n<th style=\"padding:10px 14px;background-color:#3a1a5c;color:white;font-weight:bold;text-align:left;border:1px solid #ccc;\">Parameter<\/th>\n<th style=\"padding:10px 14px;background-color:#3a1a5c;color:white;font-weight:bold;text-align:left;border:1px solid #ccc;\">Value<\/th>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Gear Ratio<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">20:1 \u2013 100:1<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">Output Speed<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">0.5 \u2013 100 rpm (metering pump range)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Output Torque<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Up to 500 Nm (standard dosing pump drives)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">Housing Options<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">Epoxy-coated cast iron; 316L SS; PVDF polymer<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Input Flange<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">IEC B5\/B14; direct motor mount<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">VFD Control<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">Compatible \u2014 variable dose rate via speed control<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Self-Locking<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Yes \u2014 prevents pump siphoning on drive stop<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">Protection Rating<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#fff;\">IP66 standard; IP67 on request<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">Operating Temp.<\/td>\n<td style=\"padding:9px 14px;border:1px solid #ddd;background:#f5f7fa;\">-10\u00b0C to +50\u00b0C standard<\/td>\n<\/tr>\n<\/table>\n<\/div>\n<p style=\"line-height:1.8;\"><strong>VFD Dose Rate Control:<\/strong> Fitting a VFD to the motor and varying input speed provides continuous dose rate adjustment without stopping the pump \u2014 critical for responding to turbidity events or changing source water chemistry. The worm drive&#8217;s smooth output is preferred over direct-drive variable-speed pumps for precise, low-pulsation dosing in small-diameter pipework.<\/p>\n<h2 style=\"color:#3a1a5c;font-size:1.45em;margin:26px 0 10px;padding:8px 0 8px 14px;border-left:5px solid #3a1a5c;background:linear-gradient(to right,#3a1a5c18,transparent);\">Compliance &#038; Standards<\/h2>\n<p style=\"line-height:1.8;\">Chemical dosing worm gear drives comply with <strong>ISO 9001:2015<\/strong> and carry <strong>CE marking<\/strong>. Input flanges meet <strong style=\"font-weight:bold;\">IEC 60072 B5\/B14<\/strong> motor standards. For water utilities subject to <strong>AS\/NZS 4020<\/strong> (testing products for contact with drinking water), material certificates confirming compliance with drinking water contact material requirements are available on request. Housing treatments conform to ISO 12944 Class C4 minimum. Standard protection: <strong>IP66<\/strong>.<\/p>\n<h2 style=\"color:#3a1a5c;font-size:1.45em;margin:26px 0 10px;padding:8px 0 8px 14px;border-left:5px solid #3a1a5c;background:linear-gradient(to right,#3a1a5c18,transparent);\">Case Studies<\/h2>\n<div style=\"display:flex;flex-direction:column;gap:14px;margin:14px 0;\">\n<div style=\"background:#fff;border:1px solid #e0e0e0;border-radius:8px;padding:16px 18px;border-left:5px solid #3a1a5c;\">\n<p style=\"font-size:1.7em;margin:0 0 4px;\">\n<p style=\"font-weight:bold;color:#3a1a5c;margin:0 0 4px;\">Regional Water Authority \u2014 Queensland \u2014 Chlorine gas room dosing pump drive<\/p>\n<p style=\"margin:3px 0;font-size:.93em;\"><strong>Challenge:<\/strong> Standard aluminium alloy gearbox corroded through within 8 months in chlorine gas room at 0.5 ppm ambient Cl\u2082.<\/p>\n<p style=\"margin:3px 0;font-size:.93em;\"><strong>Solution:<\/strong> Replaced with epoxy-coated cast-iron worm gearbox with FKM seals and 316 SS external hardware; synthetic oil.<\/p>\n<p style=\"margin:3px 0;font-size:.93em;color:#1b5e20;\"><strong>Result:<\/strong> No corrosion in 30 months; gearbox confirmed serviceable at annual inspection with only oil change required.<\/p>\n<\/div>\n<div style=\"background:#fff;border:1px solid #e0e0e0;border-radius:8px;padding:16px 18px;border-left:5px solid #3a1a5c;\">\n<p style=\"font-size:1.7em;margin:0 0 4px;\">\n<p style=\"font-weight:bold;color:#3a1a5c;margin:0 0 4px;\">Industrial WTP \u2014 Hunter Valley, NSW \u2014 Lime slurry pump drive for pH correction<\/p>\n<p style=\"margin:3px 0;font-size:.93em;\"><strong>Challenge:<\/strong> Lime slurry crystallised on standard shaft seal, causing seal failure and slurry ingress into gearbox within 6 months.<\/p>\n<p style=\"margin:3px 0;font-size:.93em;\"><strong>Solution:<\/strong> Specified dual-lip seal with grease-purge port; abrasion-resistant shaft surface; increased oil-change frequency to annual.<\/p>\n<p style=\"margin:3px 0;font-size:.93em;color:#1b5e20;\"><strong>Result:<\/strong> No seal failure in 2 years; lime crystallisation eliminated by purge-grease barrier; 24\/7 operation maintained.<\/p>\n<\/div>\n<div style=\"background:#fff;border:1px solid #e0e0e0;border-radius:8px;padding:16px 18px;border-left:5px solid #3a1a5c;\">\n<p style=\"font-size:1.7em;margin:0 0 4px;\">\n<p style=\"font-weight:bold;color:#3a1a5c;margin:0 0 4px;\">Desalination Pre-Treatment \u2014 Esperance, WA \u2014 Coagulant dosing pump gearbox<\/p>\n<p style=\"margin:3px 0;font-size:.93em;\"><strong>Challenge:<\/strong> Variable-flow requirement caused frequent manual dose rate adjustment \u2014 8 interventions per day by operators.<\/p>\n<p style=\"margin:3px 0;font-size:.93em;\"><strong>Solution:<\/strong> Added VFD to existing motor; worm gearbox confirmed compatible from 5 Hz; dose rate now adjusted via SCADA.<\/p>\n<p style=\"margin:3px 0;font-size:.93em;color:#1b5e20;\"><strong>Result:<\/strong> Operator intervention reduced from 8\u00d7\/day to zero; dosing accuracy improved from \u00b120% to \u00b13% of target.<\/p>\n<\/div>\n<\/div>\n<h2 style=\"color:#3a1a5c;font-size:1.45em;margin:26px 0 10px;padding:8px 0 8px 14px;border-left:5px solid #3a1a5c;background:linear-gradient(to right,#3a1a5c18,transparent);\">Our Advantages for Water Treatment Operators<\/h2>\n<div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(200px,1fr));gap:14px;margin:14px 0;\">\n<div style=\"background:#f8f9fa;border-radius:8px;padding:16px;border-bottom:3px solid #3a1a5c;\"><span style=\"font-size:1.9em;\">\u2697\ufe0f<\/span><\/p>\n<p style=\"font-weight:bold;color:#3a1a5c;margin:6px 0 4px;font-size:.95em;\">Chemical-Specific Materials<\/p>\n<p style=\"font-size:.88em;color:#555;margin:0;line-height:1.5;\">Housing, shaft, and seal materials matched to your specific dosing chemical.<\/p>\n<\/div>\n<div style=\"background:#f8f9fa;border-radius:8px;padding:16px;border-bottom:3px solid #3a1a5c;\"><span style=\"font-size:1.9em;\"> <\/span><\/p>\n<p style=\"font-weight:bold;color:#3a1a5c;margin:6px 0 4px;font-size:.95em;\">Anti-Siphon Self-Lock<\/p>\n<p style=\"font-size:.88em;color:#555;margin:0;line-height:1.5;\">Worm self-locking prevents backflow siphoning when drive stops \u2014 eliminates check valve in some systems.<\/p>\n<\/div>\n<div style=\"background:#f8f9fa;border-radius:8px;padding:16px;border-bottom:3px solid #3a1a5c;\"><span style=\"font-size:1.9em;\"> <\/span><\/p>\n<p style=\"font-weight:bold;color:#3a1a5c;margin:6px 0 4px;font-size:.95em;\">SCADA-Compatible<\/p>\n<p style=\"font-size:.88em;color:#555;margin:0;line-height:1.5;\">VFD-compatible drive enables remote dose rate control and monitoring from plant control room.<\/p>\n<\/div>\n<div style=\"background:#f8f9fa;border-radius:8px;padding:16px;border-bottom:3px solid #3a1a5c;\"><span style=\"font-size:1.9em;\"> <\/span><\/p>\n<p style=\"font-weight:bold;color:#3a1a5c;margin:6px 0 4px;font-size:.95em;\">AS\/NZS 4020 Materials<\/p>\n<p style=\"font-size:.88em;color:#555;margin:0;line-height:1.5;\">Drinking water contact material certificates available for all housing and shaft materials.<\/p>\n<\/div>\n<div style=\"background:#f8f9fa;border-radius:8px;padding:16px;border-bottom:3px solid #3a1a5c;\"><span style=\"font-size:1.9em;\"> <\/span><\/p>\n<p style=\"font-weight:bold;color:#3a1a5c;margin:6px 0 4px;font-size:.95em;\">Chemical-Grade Spare Parts<\/p>\n<p style=\"font-size:.88em;color:#555;margin:0;line-height:1.5;\">FKM, PTFE, and Hastelloy seal and shaft kits stocked \u2014 critical spares always available.<\/p>\n<\/div>\n<\/div>\n<h2 style=\"color:#3a1a5c;font-size:1.45em;margin:26px 0 10px;padding:8px 0 8px 14px;border-left:5px solid #3a1a5c;background:linear-gradient(to right,#3a1a5c18,transparent);\">Frequently Asked Questions<\/h2>\n<details style=\"margin-bottom:9px;border:1px solid #ddd;border-radius:5px;overflow:hidden;\">\n<summary style=\"padding:12px 15px;background:#3a1a5c;color:#fff;cursor:pointer;font-weight:600;list-style:none;\">&#9654; How does a worm gearbox prevent pump siphoning when the dosing pump stops?<\/summary>\n<div style=\"padding:12px 15px;background:#f9f9f9;line-height:1.75;font-size:.97em;\">At gear ratios \u2265 30:1, the worm gear is mechanically self-locking \u2014 the output shaft cannot be back-driven by back pressure in the dosing line. This prevents residual pipeline pressure from forcing fluid backward through the pump when the motor stops, eliminating uncontrolled chemical discharge and over-dosing between cycles.<\/div>\n<\/details>\n<details style=\"margin-bottom:9px;border:1px solid #ddd;border-radius:5px;overflow:hidden;\">\n<summary style=\"padding:12px 15px;background:#3a1a5c;color:#fff;cursor:pointer;font-weight:600;list-style:none;\">&#9654; What housing material should I specify for sodium hypochlorite dosing?<\/summary>\n<div style=\"padding:12px 15px;background:#f9f9f9;line-height:1.75;font-size:.97em;\">For NaOCl concentrations up to 15% (trade bleach), epoxy-coated cast iron with FKM seals and 316L SS external fasteners is adequate. For higher concentrations or prolonged splash\/vapour exposure, 316L SS or PVDF polymer housing is preferred. Aluminium alloy housings should never be used \u2014 hypochlorite rapidly attacks aluminium.<\/div>\n<\/details>\n<details style=\"margin-bottom:9px;border:1px solid #ddd;border-radius:5px;overflow:hidden;\">\n<summary style=\"padding:12px 15px;background:#3a1a5c;color:#fff;cursor:pointer;font-weight:600;list-style:none;\">&#9654; Can a single worm gearbox drive two dosing pumps on a common shaft?<\/summary>\n<div style=\"padding:12px 15px;background:#f9f9f9;line-height:1.75;font-size:.97em;\">Yes \u2014 a double-output (DS-type) worm gearbox with shaft extensions on both sides can drive two synchronised dosing pumps from a single motor. This is used in dual-chemical dosing systems where dose ratio is fixed. For variable-ratio dosing, two separate gearboxes with independent VFDs are preferred.<\/div>\n<\/details>\n<details style=\"margin-bottom:9px;border:1px solid #ddd;border-radius:5px;overflow:hidden;\">\n<summary style=\"padding:12px 15px;background:#3a1a5c;color:#fff;cursor:pointer;font-weight:600;list-style:none;\">&#9654; What is the effect of low ambient temperature on chemical dosing gearbox performance?<\/summary>\n<div style=\"padding:12px 15px;background:#f9f9f9;line-height:1.75;font-size:.97em;\">Below 0\u00b0C, standard mineral gear oil thickens, reducing lubrication film at start-up. For dosing rooms in cold climates, specify synthetic ISO VG 100 or VG 150 gear oil with a pour point \u2264 \u221240\u00b0C to ensure adequate oil flow at cold-start conditions. This is relevant for mountain reservoir and alpine water treatment facilities in Australia.<\/div>\n<\/details>\n<details style=\"margin-bottom:9px;border:1px solid #ddd;border-radius:5px;overflow:hidden;\">\n<summary style=\"padding:12px 15px;background:#3a1a5c;color:#fff;cursor:pointer;font-weight:600;list-style:none;\">&#9654; How often should gear oil be changed in a chemical dosing pump gearbox?<\/summary>\n<div style=\"padding:12px 15px;background:#f9f9f9;line-height:1.75;font-size:.97em;\">With synthetic oil and clean sealing, change intervals of 3,000\u20135,000 hours are typical. In corrosive chemical atmospheres where acid or chlorine vapour slowly degrades oil additives, annual oil analysis is recommended. Change on analysis result rather than fixed interval in aggressive chemical environments.<\/div>\n<\/details>\n<div style=\"background:#3a1a5c;color:#fff;border-radius:10px;padding:28px 24px;text-align:center;margin:28px 0;\">\n<h2 style=\"color:#fff;margin:0 0 8px;\">Specify the Right Drive for Your Dosing Application<\/h2>\n<p style=\"margin:0 0 18px;\">Chemical-resistant worm gear drives matched to your specific process chemistry.<\/p>\n<p><a href=\"https:\/\/gearboxesworm.xyz\/th\/contact-us\/\" style=\"background:#fff;color:#3a1a5c;padding:11px 26px;border-radius:5px;font-weight:bold;text-decoration:none;margin:5px;display:inline-block;\">&#9993; Request a Quote<\/a><a href=\"https:\/\/gearboxesworm.xyz\/th\/products\/\" style=\"border:2px solid #fff;color:#fff;padding:11px 26px;border-radius:5px;font-weight:bold;text-decoration:none;margin:5px;display:inline-block;\">&#128295; View Products<\/a><\/div>","protected":false},"excerpt":{"rendered":"<p>Worm Gearbox for Chemical Dosing Pump \u2014 Precise, Corrosion-Resistant Metering Drive Chemical dosing pumps in water treatment plants precisely deliver chlorine, sodium hypochlorite, polymers, lime slurry, and pH-adjustment acids at accurately controlled feed rates. A worm gear speed reducer driving a metering pump must provide stable, vibration-free output at very low speeds (often below 30 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[9129],"tags":[9139,9132,9141,9140,9142,9137,9138],"class_list":["post-3297","post","type-post","status-publish","format-standard","hentry","category-water-treatment","tag-chemical-resistant-worm-gearbox","tag-corrosion-resistant-worm-gear-unit","tag-ip66-worm-gearbox-chemical","tag-worm-drive-reducer-water-treatment","tag-worm-gear-reducer-dosing-pump","tag-worm-gearbox-chemical-dosing","tag-worm-reducer-metering-pump"],"_links":{"self":[{"href":"https:\/\/gearboxesworm.xyz\/th\/wp-json\/wp\/v2\/posts\/3297","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gearboxesworm.xyz\/th\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gearboxesworm.xyz\/th\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gearboxesworm.xyz\/th\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gearboxesworm.xyz\/th\/wp-json\/wp\/v2\/comments?post=3297"}],"version-history":[{"count":0,"href":"https:\/\/gearboxesworm.xyz\/th\/wp-json\/wp\/v2\/posts\/3297\/revisions"}],"wp:attachment":[{"href":"https:\/\/gearboxesworm.xyz\/th\/wp-json\/wp\/v2\/media?parent=3297"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gearboxesworm.xyz\/th\/wp-json\/wp\/v2\/categories?post=3297"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gearboxesworm.xyz\/th\/wp-json\/wp\/v2\/tags?post=3297"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}